248 Extreme Networks Consolidated Hardware Guide
BlackDiamond 6800 Series I/O Modules
Table 71 describes the cable specifications for the RJ-21 connector. Appropriate cables are available from
your local supplier.
To access the ports, use a 180-degree male RJ-21 connector with a shielded PVC trunk cable and secure
to a maximum of 4 in-lbs of torque. You can access the ports in one of the following ways:
• Through a patch panel by terminating the cable and shield with an RJ-21 connector.
• Directly by using a cable that is terminated with 12 RJ-45 connectors.
The RJ-21 connector is shown in Figure 125.
Figure 125: RJ-21 connector
The default configuration of the F96Ti module is as follows. All ports:
• Are added to the default VLAN as untagged.
• Inherit the properties of the default VLAN (protocol type, VLANid, and so forth).
• Operate in auto-negotiation mode.
LEDs
The F96Ti module has a module status LED.
For information about the module status LED and its activity on the F96Ti module, see “I/O Module
LEDs” on page 271.
23
24
RxD (-)
TxD (-)
48
49
RxD (+)
TxD (+)
Table 71: F96Ti cable specifications
Connectors Cable Min Length Max Length Max Torque
Lucent 525 Telco 50-pin RJ-21 Shielded trunk cable with 12
CAT5 twisted pairs
1 m 100 m 4 in-lbs
Table 70: Output signals for the RJ-21 connector (continued)