40 ExtremeWare Error Message Decoder
Emergency Error Messages
POST Failure
<INFO:DIAG> Slot 1 failed PQM internal memory test
<WARN:DIAG> Slot 1 PQM ASIC failed register test
<WARN:DIAG> Slot 1 failed FDB memory test
<CRIT:DIAG> FDB extension memory bus failed at data bit
<WARN:DIAG> Slot 1 failed VPST memory test
<CRIT:DIAG> VPST memory bus test failed at data bit 19
<WARN:DIAG> Slot 1 AFC ASIC failed register test
<CRIT:DIAG> Slot 1 RR No. 7 failed ASIC register test
Software Version
All ExtremeWare
Hardware Version
All
Explanation
These messages indicate that a slot (slot 1) has failed the Power On Self Test (POST); therefore, it is a
hardware problem.
Action
Replace the I/O module in the slot (slot 1).