Vista de página 788
Master Node State Changed to Failed
ExtremeWare Error Message Decoder 789
Master Node State Changed to Failed
<INFO:EAPS> eaps_runtime.c 2619: State Change, Complete => Failed, EAPS="E05B"
Software Version
ExtremeWare 6.2.2 or later
Hardware Version
All
Explanation
This message indicates that the EAPS master node detected a failure in the ring. This causes its state to
transition from Complete to Failed, and opens its secondary port.
Action
Restore the link on the port that caused the master to go into Failed state.