Vista de página 508
Invalid ESD Instance: Cannot Set Shared Port Timeout
ExtremeWare Error Message Decoder 509
Invalid ESD Instance: Cannot Set Shared Port Timeout
Could not set the shared-port-timeout. Invalid ESD instance %d
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” series
Explanation
This message indicates that the ESD (EAPS super domain) instance entered is not a valid ESD instance.
You can set the shared-port-timeout only if the ESD instance is valid.
Action
1 Check number of ESD instance exist in the system. You can create a maximum of 2 ESD instance on
a switch.
2 Delete the ESD instance that and create the ESD instance again.