Extreme Networks WM-4T1i Especificações Página 53

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 306
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 52
Extreme Networks Consolidated Hardware Guide 2-9
Meeting Site Requirements
The air flow of the BlackDiamond 6800 series chassis moves through the power
supplies and is independent of the airflow through the modules as shown in Figure 2-4
and Figure 2-5. For example, if the power supply fans fail, the air flow through the
module area of the chassis will not cool down the power supplies.
Air flow for cooling power supplies moves front to back as you face the chassis.
Air flow for cooling modules moves left to right as you face the chassis.
Figure 2-4: Air flow through the BlackDiamond 6816 chassis
BD_032
POWER POWER
1
2
3
4
5
6
7
8
A
B
C
D
9
10
11
12
13
14
15
16
POWER POWER
Air flow through
power supplies
Air flow
through
chassis
Vista de página 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 305 306

Comentários a estes Manuais

Sem comentários